Review




Structured Review

InDevR Inc mrna oligo binding buffer
( a ) Schematic of each <t>mRNA</t> construct with naming and binding locations of the capture oligos. Performance results for blue-shaded capture oligos are the focus of this work. ( b ) Microarray layout where each capture <t>oligo</t> was printed in triplicate in three locations on the microarray (n = 9 spots). ( c ) Schematic of the assay detection principle, in which each printed capture oligo can bind an mRNA construct in a sequence-specific manner and be fluorescently labeled via the polyA tail. ( d ) Representative fluorescence images of each monovalent encapsulated mRNA construct captured and labeled on the microarray, as well as a quadrivalent mixture of the four mRNA constructs, each at a sample concentration of 20 µg/mL. The relevant capture oligos are highlighted for each monovalent sample, with brighter green indicating a higher fluorescence signal.
Mrna Oligo Binding Buffer, supplied by InDevR Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/mrna oligo binding buffer/product/InDevR Inc
Average 90 stars, based on 1 article reviews
mrna oligo binding buffer - by Bioz Stars, 2026-06
90/100 stars

Images

1) Product Images from "Analytical Performance of a Multiplexed Microarray Assay for Rapid Identification and Quantification of a Multivalent mRNA Vaccine"

Article Title: Analytical Performance of a Multiplexed Microarray Assay for Rapid Identification and Quantification of a Multivalent mRNA Vaccine

Journal: Vaccines

doi: 10.3390/vaccines12101144

( a ) Schematic of each mRNA construct with naming and binding locations of the capture oligos. Performance results for blue-shaded capture oligos are the focus of this work. ( b ) Microarray layout where each capture oligo was printed in triplicate in three locations on the microarray (n = 9 spots). ( c ) Schematic of the assay detection principle, in which each printed capture oligo can bind an mRNA construct in a sequence-specific manner and be fluorescently labeled via the polyA tail. ( d ) Representative fluorescence images of each monovalent encapsulated mRNA construct captured and labeled on the microarray, as well as a quadrivalent mixture of the four mRNA constructs, each at a sample concentration of 20 µg/mL. The relevant capture oligos are highlighted for each monovalent sample, with brighter green indicating a higher fluorescence signal.
Figure Legend Snippet: ( a ) Schematic of each mRNA construct with naming and binding locations of the capture oligos. Performance results for blue-shaded capture oligos are the focus of this work. ( b ) Microarray layout where each capture oligo was printed in triplicate in three locations on the microarray (n = 9 spots). ( c ) Schematic of the assay detection principle, in which each printed capture oligo can bind an mRNA construct in a sequence-specific manner and be fluorescently labeled via the polyA tail. ( d ) Representative fluorescence images of each monovalent encapsulated mRNA construct captured and labeled on the microarray, as well as a quadrivalent mixture of the four mRNA constructs, each at a sample concentration of 20 µg/mL. The relevant capture oligos are highlighted for each monovalent sample, with brighter green indicating a higher fluorescence signal.

Techniques Used: Construct, Binding Assay, Microarray, Sequencing, Labeling, Fluorescence, Concentration Assay

Reactivity and specificity of monovalent  mRNA  constructs encapsulated in LNPs at 5 µg/mL.
Figure Legend Snippet: Reactivity and specificity of monovalent mRNA constructs encapsulated in LNPs at 5 µg/mL.

Techniques Used: Construct

Analytical sensitivity and range for  mRNA  encapsulated in LNPs.
Figure Legend Snippet: Analytical sensitivity and range for mRNA encapsulated in LNPs.

Techniques Used:

Precision and accuracy of  mRNA  encapsulated in LNPs.
Figure Legend Snippet: Precision and accuracy of mRNA encapsulated in LNPs.

Techniques Used:

Reactivity and specificity of naked  mRNA  at 20 µg/mL.
Figure Legend Snippet: Reactivity and specificity of naked mRNA at 20 µg/mL.

Techniques Used:

( a – d ) Representative calibration curves from a quadrivalent mixture of naked mRNA are shown for each capture oligo: ( a – c ) were fit to a quadratic regression with R 2 ≥ 0.99, and ( d ) D(i) was fit to a 4PL regression with R 2 ≥ 0.99.
Figure Legend Snippet: ( a – d ) Representative calibration curves from a quadrivalent mixture of naked mRNA are shown for each capture oligo: ( a – c ) were fit to a quadratic regression with R 2 ≥ 0.99, and ( d ) D(i) was fit to a 4PL regression with R 2 ≥ 0.99.

Techniques Used:

Precision and accuracy (naked and unencapsulated  mRNA).
Figure Legend Snippet: Precision and accuracy (naked and unencapsulated mRNA).

Techniques Used:



Similar Products

90
InDevR Inc mrna oligo binding buffer
( a ) Schematic of each <t>mRNA</t> construct with naming and binding locations of the capture oligos. Performance results for blue-shaded capture oligos are the focus of this work. ( b ) Microarray layout where each capture <t>oligo</t> was printed in triplicate in three locations on the microarray (n = 9 spots). ( c ) Schematic of the assay detection principle, in which each printed capture oligo can bind an mRNA construct in a sequence-specific manner and be fluorescently labeled via the polyA tail. ( d ) Representative fluorescence images of each monovalent encapsulated mRNA construct captured and labeled on the microarray, as well as a quadrivalent mixture of the four mRNA constructs, each at a sample concentration of 20 µg/mL. The relevant capture oligos are highlighted for each monovalent sample, with brighter green indicating a higher fluorescence signal.
Mrna Oligo Binding Buffer, supplied by InDevR Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/mrna oligo binding buffer/product/InDevR Inc
Average 90 stars, based on 1 article reviews
mrna oligo binding buffer - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
InDevR Inc 2x mrna oligo binding buffer vxi-6316
( a ) Schematic of each <t>mRNA</t> construct with naming and binding locations of the capture oligos. Performance results for blue-shaded capture oligos are the focus of this work. ( b ) Microarray layout where each capture <t>oligo</t> was printed in triplicate in three locations on the microarray (n = 9 spots). ( c ) Schematic of the assay detection principle, in which each printed capture oligo can bind an mRNA construct in a sequence-specific manner and be fluorescently labeled via the polyA tail. ( d ) Representative fluorescence images of each monovalent encapsulated mRNA construct captured and labeled on the microarray, as well as a quadrivalent mixture of the four mRNA constructs, each at a sample concentration of 20 µg/mL. The relevant capture oligos are highlighted for each monovalent sample, with brighter green indicating a higher fluorescence signal.
2x Mrna Oligo Binding Buffer Vxi 6316, supplied by InDevR Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/2x mrna oligo binding buffer vxi-6316/product/InDevR Inc
Average 90 stars, based on 1 article reviews
2x mrna oligo binding buffer vxi-6316 - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

Image Search Results


( a ) Schematic of each mRNA construct with naming and binding locations of the capture oligos. Performance results for blue-shaded capture oligos are the focus of this work. ( b ) Microarray layout where each capture oligo was printed in triplicate in three locations on the microarray (n = 9 spots). ( c ) Schematic of the assay detection principle, in which each printed capture oligo can bind an mRNA construct in a sequence-specific manner and be fluorescently labeled via the polyA tail. ( d ) Representative fluorescence images of each monovalent encapsulated mRNA construct captured and labeled on the microarray, as well as a quadrivalent mixture of the four mRNA constructs, each at a sample concentration of 20 µg/mL. The relevant capture oligos are highlighted for each monovalent sample, with brighter green indicating a higher fluorescence signal.

Journal: Vaccines

Article Title: Analytical Performance of a Multiplexed Microarray Assay for Rapid Identification and Quantification of a Multivalent mRNA Vaccine

doi: 10.3390/vaccines12101144

Figure Lengend Snippet: ( a ) Schematic of each mRNA construct with naming and binding locations of the capture oligos. Performance results for blue-shaded capture oligos are the focus of this work. ( b ) Microarray layout where each capture oligo was printed in triplicate in three locations on the microarray (n = 9 spots). ( c ) Schematic of the assay detection principle, in which each printed capture oligo can bind an mRNA construct in a sequence-specific manner and be fluorescently labeled via the polyA tail. ( d ) Representative fluorescence images of each monovalent encapsulated mRNA construct captured and labeled on the microarray, as well as a quadrivalent mixture of the four mRNA constructs, each at a sample concentration of 20 µg/mL. The relevant capture oligos are highlighted for each monovalent sample, with brighter green indicating a higher fluorescence signal.

Article Snippet: Slides were pre-washed by adding 50 µL of mRNA Wash Buffer 1 (VXI-6317, InDevR Inc.) to each well and incubated for 1 min. Calibrants and/or samples were diluted in 1x mRNA Oligo Binding Buffer (VX-6316, InDevR Inc.) to a final 1x concentration with 2% Zwittergent 3–14.

Techniques: Construct, Binding Assay, Microarray, Sequencing, Labeling, Fluorescence, Concentration Assay

Reactivity and specificity of monovalent  mRNA  constructs encapsulated in LNPs at 5 µg/mL.

Journal: Vaccines

Article Title: Analytical Performance of a Multiplexed Microarray Assay for Rapid Identification and Quantification of a Multivalent mRNA Vaccine

doi: 10.3390/vaccines12101144

Figure Lengend Snippet: Reactivity and specificity of monovalent mRNA constructs encapsulated in LNPs at 5 µg/mL.

Article Snippet: Slides were pre-washed by adding 50 µL of mRNA Wash Buffer 1 (VXI-6317, InDevR Inc.) to each well and incubated for 1 min. Calibrants and/or samples were diluted in 1x mRNA Oligo Binding Buffer (VX-6316, InDevR Inc.) to a final 1x concentration with 2% Zwittergent 3–14.

Techniques: Construct

Analytical sensitivity and range for  mRNA  encapsulated in LNPs.

Journal: Vaccines

Article Title: Analytical Performance of a Multiplexed Microarray Assay for Rapid Identification and Quantification of a Multivalent mRNA Vaccine

doi: 10.3390/vaccines12101144

Figure Lengend Snippet: Analytical sensitivity and range for mRNA encapsulated in LNPs.

Article Snippet: Slides were pre-washed by adding 50 µL of mRNA Wash Buffer 1 (VXI-6317, InDevR Inc.) to each well and incubated for 1 min. Calibrants and/or samples were diluted in 1x mRNA Oligo Binding Buffer (VX-6316, InDevR Inc.) to a final 1x concentration with 2% Zwittergent 3–14.

Techniques:

Precision and accuracy of  mRNA  encapsulated in LNPs.

Journal: Vaccines

Article Title: Analytical Performance of a Multiplexed Microarray Assay for Rapid Identification and Quantification of a Multivalent mRNA Vaccine

doi: 10.3390/vaccines12101144

Figure Lengend Snippet: Precision and accuracy of mRNA encapsulated in LNPs.

Article Snippet: Slides were pre-washed by adding 50 µL of mRNA Wash Buffer 1 (VXI-6317, InDevR Inc.) to each well and incubated for 1 min. Calibrants and/or samples were diluted in 1x mRNA Oligo Binding Buffer (VX-6316, InDevR Inc.) to a final 1x concentration with 2% Zwittergent 3–14.

Techniques:

Reactivity and specificity of naked  mRNA  at 20 µg/mL.

Journal: Vaccines

Article Title: Analytical Performance of a Multiplexed Microarray Assay for Rapid Identification and Quantification of a Multivalent mRNA Vaccine

doi: 10.3390/vaccines12101144

Figure Lengend Snippet: Reactivity and specificity of naked mRNA at 20 µg/mL.

Article Snippet: Slides were pre-washed by adding 50 µL of mRNA Wash Buffer 1 (VXI-6317, InDevR Inc.) to each well and incubated for 1 min. Calibrants and/or samples were diluted in 1x mRNA Oligo Binding Buffer (VX-6316, InDevR Inc.) to a final 1x concentration with 2% Zwittergent 3–14.

Techniques:

( a – d ) Representative calibration curves from a quadrivalent mixture of naked mRNA are shown for each capture oligo: ( a – c ) were fit to a quadratic regression with R 2 ≥ 0.99, and ( d ) D(i) was fit to a 4PL regression with R 2 ≥ 0.99.

Journal: Vaccines

Article Title: Analytical Performance of a Multiplexed Microarray Assay for Rapid Identification and Quantification of a Multivalent mRNA Vaccine

doi: 10.3390/vaccines12101144

Figure Lengend Snippet: ( a – d ) Representative calibration curves from a quadrivalent mixture of naked mRNA are shown for each capture oligo: ( a – c ) were fit to a quadratic regression with R 2 ≥ 0.99, and ( d ) D(i) was fit to a 4PL regression with R 2 ≥ 0.99.

Article Snippet: Slides were pre-washed by adding 50 µL of mRNA Wash Buffer 1 (VXI-6317, InDevR Inc.) to each well and incubated for 1 min. Calibrants and/or samples were diluted in 1x mRNA Oligo Binding Buffer (VX-6316, InDevR Inc.) to a final 1x concentration with 2% Zwittergent 3–14.

Techniques:

Precision and accuracy (naked and unencapsulated  mRNA).

Journal: Vaccines

Article Title: Analytical Performance of a Multiplexed Microarray Assay for Rapid Identification and Quantification of a Multivalent mRNA Vaccine

doi: 10.3390/vaccines12101144

Figure Lengend Snippet: Precision and accuracy (naked and unencapsulated mRNA).

Article Snippet: Slides were pre-washed by adding 50 µL of mRNA Wash Buffer 1 (VXI-6317, InDevR Inc.) to each well and incubated for 1 min. Calibrants and/or samples were diluted in 1x mRNA Oligo Binding Buffer (VX-6316, InDevR Inc.) to a final 1x concentration with 2% Zwittergent 3–14.

Techniques: